MIL-DTL-17060G(SH)
APPENDIX D
TEST REPORT TECHNICAL CONTENT REQUIREMENTS
D.1. SCOPE
D.1.1 Scope. This appendix identifies specific content requirements pertinent to the submittal of test reports.
When specified in the contract or order (see 6.2), this appendix is a mandatory part of the specification. The
information contained herein is intended for compliance.
D.2. TEST REPORT CONTENT REQUIREMENTS
D.2.1 Cover and title page. The following information shall appear on the outside front cover and title page:
a.
Report date.
b.
Report number (contractor or government).
c.
Contractor's name, address, and commercial and Government entity code.
d.
Contract number and contract line item number or sequence number (if applicable)
e. Type of test/inspection (for example, first article acceptance test, conformance inspection, developmental
test, qualification test, environmental test).
f.
Identification of item tested/inspected.
g.
Date or period of test/inspection.
h.
Name and address of requiring Government activity.
i.
Security classification, downgrading and declassifying information, if applicable.
D.2.2 First article inspection report. The report shall contain results of the first article tests/inspections of table
XVIII as follows:
a. When specified, the material test (see 4.6.1) shall be performed to verify compliance of contractor selected
material(s) with the minimum requirements of this specification. Test data shall be provided that compares each
material characteristic identified for the minimum material requirement(s) of this specification with those of the
selected material.
b. The results of the assembly inspection (see 4.6.2) shall be forwarded. Each item of the inspection shall be
addressed.
c.
The resistance between each pair of motor leads and the ambient temperature shall be furnished (see 4.6.3).
d.
Observed results of the lubrication system shall be shown (see 4.6.4).
e.
The measured airborne noise levels shall be shown for each specified octave band (see 4.6.5.1).
The measured structureborne noise levels shall be shown for each specified octave band (see 4.6.5.2).
f.
g. The maximum amplitude of vibration and the motor speed at which the vibration was measured shall be
shown (see 4.6.6).
The bearing end play shall be shown (see 4.6.7).
h.
Results of the enclosure effectiveness test addressing all acceptance criteria shall be shown (see 4.6.8).
i.
j. No-load input data shall consist of the amount of operating time prior to the measurements, input watts,
speed and line volts and amperes for each phase (see 4.6.10).
k. Locked-rotor data shall consist of current, watts, voltage and torque at locked-rotor, pull-up, and
breakdown. The KVA limits of the test facility shall be shown. For testing at reduced voltage, all measured and
calculated data shall be shown (see 4.6.11).
l. Load test data shall consist of percent rated load, speed, watts, amps, efficiency, and power factor at 0, 25,
50, 75, 100, and 125 percent of rated load (see 4.6.12).
m. The phase characteristic test for synchronous motors shall contain measurements of field and armature
current sufficient to plot a "vee" curve (see 4.6.13).
86
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business