MIL-DTL-17060G(SH)
APPENDIX F
(4) Results
d.
Monitored performance. See table F-II for a sample tabulation format for required information.
(1) Blow number
(2) Drop feet
(3) Axis
(4) Operating mode
(5) Reference measurements
(6) Post-test measurements or corrections
e.
Survey findings, noting any damage and providing damage photographs.
f.
Modifications, if any, accomplished prior to or during test with applicable rationale, description, etc.
g.
Remarks.
h. If witnessed by a designated Government representative, the report shall include signature of witness and
certification of test report.
i.
Certification of report by the test laboratory.
TABLE F-II. Medium shock machine test monitored performance.
Operating mode
Blow
Post-test
Reference
Group
(on, off, open,
numbe
measurements or
measurements
Drop feet
Axis
number
1/
conditions 1/ 2/
closed, etc.)
r
1
I Vertical
2
II Vertical
3
III Vertical
I Inclined 3/
4
II Inclined 3/
5
III Inclined 3/
6
NOTES:
1/
Volts, ampere, revolutions per minute, pounds per square inch, alignment, clearances, bolting torques, etc.
2/
Yielding, cracking, short-circuiting, separating, unlatching, unbalanced, etc.
3/
Provide angle of inclination.
F.3.4 Heavyweight shock test on a floating shock platform (FSP) or large floating shock platform (LFSP). The
following information shall be included for all FSP and LFSP tests as defined by MIL-S-901:
a.
Test platform as defined by MIL-S-901.
b. Test fixture description including details of the installations. Photographs or sketches of the foundation and
installation.
c.
Total weight on the platform.
d.
Instrumentation.
(1) Gauge type
(2) Location
(3) Orientation
(4) Results
e.
Monitored performance. See table F-III for a sample tabulation format for required information.