MIL-DTL-17060G(SH)
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
IEC 60034-18-41
-
Qualification and Type Tests for Type 1 Electrical Insulation Systems Used in
Rotating Electrical Machines Fed From Voltage Converters
IEC 61934
-
Electrical Measurements of Partial Discharge (PD) During Short Rise Time and
Repetitive Voltage Impulses
(Copies of these documents are available from the IEC, 3 rue de Varembé, P.O. Box 131, CH-1211 Geneva 20,
Switzerland or online at www.iec.ch.)
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA)
NEMA MW1000
-
Magnet Wire
(Copies of this document are available from the National Electrical Manufacturers Association, 1300 North 17th
Street, Suite 1847, Rosslyn, VA 22209 or online at www.nema.org.)
SAE INTERNATIONAL
SAE AMS2469
-
Hard Anodic Coating on Aluminum and Aluminum Alloys
SAE AMS7259
-
Packing, Preformed - O-Ring Seal
SAE AMS7276
-
Packing, Preformed - O-Ring Seal
(Copies of these documents are available from SAE World Headquarters, 400 Commonwealth Drive,
Warrendale, PA 15096-0001 or online at www.sae.org.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between
the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this
document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 6.4) in
accordance with 4.2.
3.2 Reliability. Bearings shall be selected to provide a calculated B-10 life of not less than 10,000 hours.
Bearing life shall be calculated in accordance with ABMA 9 for single bearings and, unless otherwise specified (see
6.2), in accordance with MIL-B-17931 for duplex bearings. Bearing life extension factors, identified in ABMA 9,
shall not be used in bearing life calculations.
3.3 Materials, parts, and processes. Unless otherwise specified herein, materials, parts, and processes shall be
in accordance with MIL-E-917.
3.3.1 Hazardous material. Materials and parts containing asbestos, cadmium, lithium, mercury, radioactive
materials, or materials giving off toxic fumes under operation shall not be used.
3.3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally
preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the
operational and maintenance requirements, and promotes economically advantageous life cycle costs.
3.3.3 Material compatibility. Materials which (through outgassing or other physical phenomena) cause
deterioration of other materials or degradation of equipment performance shall not be used.
3.4 Safety. Unless otherwise specified herein, safety shall be in accordance with MIL-E-917. The equipment
shall provide protection for personnel against accidental contact with moving parts and voltages in excess of 30 volts
root mean square (Vrms) or 30 volts direct current (Vdc).
3.5 Design and construction requirements. Motors shall be in accordance with 3.5.1 and 3.5.2. 6.3 should also
be considered.